Loading...
HomeMy WebLinkAbout12727 003964 101 12-16-2020 ATGTEST SLA AUTOMATIC TANK GAUGE TEST 66052.05 ATGTEST ADEM ANNUAL TANK GAUGE TEST REPORT FOR YEAR gmn Facilil Name: United Food and Fuel#14 Owner: McNeill Family Address: 1192 Western Blvd. Address: PO Box 11 City, County,Zip: Montgomery, Montgomery, 36108 City,State,Zip: Montgomery,AL. 36101 Facili I.D. #: 12899-101-003964 Phone#: 334-263-9070 Tester Name: Kurfts Wales Tester Phone#: 334-300-0984 Tester Company: Test Date: 12-16-20 Instructions 1. Submit a completed copy of this form within 30 days of performing test to: Groundwater Branch,PO Box 301463,Montgomery,AL 36130-1463,or fax to: (334)270-5631,or email to: USTcpmpliance(aladem.alabama.gov. 2. This form allows you to record up to 6 ADEM Unique Tank Numbers,assuming that the Facility ID Number remains the same. 3. Inspection and Testing must be performed in accordance with a nationally recognized code of practice(such as PEI RP-1200 or equivalent)or the manufacturers instructions. 4. Keep a copy of this testing for 3 years. Questions on how to complete this form should be directed to the Groundwater Branch, UST Compliance Unit at(334)270-5655. 5. If the probe is not used for leak detection but the console is(e.g.double walled tanks using interstitial monitoring),then it does not need to be tested. ADEM Unique Tank# 1 2 3 Product Stored I Gasoline Gasol ne I Diesel Automatic Tank Gauge Console Test Does console lest history include test ®yes ®yes ®yes ❑yes ❑yes ❑yes alarms?(Don't forget to clear test alarmist ❑ no ❑ no ❑no ❑ no ❑ no ❑ no Does site setup agree with configuration ®yes ®yes ®yes ❑yes ❑yes ❑yes shown in console? ❑ no ❑ no 0 no ❑ no ❑ no ❑ no Is battery backup operational? ®yes M yes IM yes ❑yes ❑yes ❑yes ❑ no ❑ no ❑ no ❑ no ❑ no ❑ no Testing results? W pass 0 pass IH pass 0 pass 0 pass ❑ pass Must meet all applicable criteria to pass. ❑fail 0 fail 0 fail 0 fail 0 fail ❑fail Probe and Float Test Is probe free of residual buildup? D yes ®yes ®yes ❑yes ❑yes ❑yes ❑ no ❑ no Ono ❑ no ❑ no ❑ no Are cables free of kinks? ®yes ®yes ®yes ❑yes ❑yes ❑yes ❑ no ❑ no Ono ❑ no ❑ no ❑ no Was shaft inspected and free of damage? IN D no lz❑ no 13❑no ❑ no ❑ no s❑ no Do floats move freely? ®yes Z yes IS yes ❑yes ❑yes ❑yes ❑ no ❑ no ❑no ❑ no ❑ no ❑ no Does measured product and water levels in E yes 0 yes 0 yes ❑yes ❑yes ❑yes tank agree with console levels? ❑ no ❑ no ❑no ❑ no ❑ no ❑ no Does actual product float level agree with tg yes ®yes ®yes ❑yes ❑yes ❑yes console product float level? ❑ no ❑ no ❑no ❑ no ❑ no ❑ no Does Overfill alarm activation level agree IN yes 0 n/a IN yes D n/a IN yes D n/a ❑yes D n/a ❑yes D n/a ❑yes 0 me with console? ❑ no ❑ no ❑no ❑ no ❑ no ❑ no Does actual water float level agree with IN yes ® yes ®yes ❑yes ❑yes ❑yes console water float level? ❑ no ❑ no ❑no ❑ no ❑ no ❑ no Does water alarm activation level agree with ta yes ®yes (A yes ❑yes ❑yes ❑yes console? ❑ no ❑ no ❑no ❑ no ❑ no ❑ no Testing results? 0 pass ®pass 12 pass 0 pass 0 pass ❑ pass (Must meet all applicable criteria to pass.) ❑fail 0 fail 0 fail 0 fail 0 fail ❑fail Repairs Needed Date of Description of any Repairs Repair Tester's Signature: Kurtis Wailes ADEM Form 565