HomeMy WebLinkAbout12724 009491 101 12-14-2020 SUMPT SLA SUMP INTEGRITY TEST 70627.86 SUMPT ADEM 3 YEAR CONTAINMENT SUMP INTEGRITY TEST REPORT Questions on how to complete this form should be directed to the Groundwater Branch,UST Compliance Section al 334 2701 Facility Name: United Food and Fuel#1 Owner: McNeill Family Address: 4521 So. Court St. Address: PO Box 11 City, County,Zip: Montgomery, Montgomery: 36105 Cit , State,Zi : Mont ome AL 36101 Facility I.D.#: 12899-101-009491 Phone#: 334-263-9070 Tester Name: Kurtis Wailes Tester Phone#: 334-300-0984 Tester Company: Instructions 1. R a low level rest Is to be performed,do not use this form. Instead,use ADEM 3 Year Containment Sump Integrity Test Report(Low Level Method)form to document the results which can be found on the ADEM website at www.adem.alabama.gov/orogramstwatertgroundwater.cnt. 2. Submit a completed copy of this form within 30 days of performing the lest to: Groundwater Branch, PO Box 301463 Montgomery, AL 36130-1463,or fax to: (334)270-5631 or by email to: USTcompliancera-adem.alabama.gov. 3. This form allows you to record up to 5 ADEM Unique Tank Numbers,assuming that the Facility ID Number and the test method remain the same. 4. Double walled containment sumps do not require testing. 5. Single and double walled containment sumps must also be checked annually in accordance with the Walkthrough Inspection requirements. See ADEM Annual Walkthrough Inspection Checklist Log which can be found on the ADEM website at www.adem.alabama.gov/progmms/water/groundwater.cnt. 6. Testing must be performed in accordance with a nationally recognized mile of practice(such as PEI RP-1200 or equivalent)or the manufacturer's instructions. 7. Keep a record copy of this testing for 3 years. Code of Practice or Manufacturer's Instructions used: ADEM Unique Tank# 1 2 3 or Owner's Dispenser# Products Gasoline Gasoline Diesel (N/A foror di tlispensenser) ®sub pump ®sub pump ®sub pump ❑sub pump ❑sub pump Type of sump tested ❑intermediate ❑ intermediate ❑intermediate ❑intermediate ❑intermediate ❑dispenser ❑dispenser ❑dispenser ❑dispenser ❑dispenser ❑vacuum ❑vacuum ❑vacuum ❑vacuum ❑vacuum ❑pressure ❑ pressure ❑pressure ❑pressure ❑pressure Test method used ®hydrostatic El hydrostatic ID hydrostatic ❑hydrostatic ❑hydrostatic ❑manufacturer's ❑ manufacturers ❑manufacturer's ❑manufacturer's ❑manufacturer's instructions instructions instructions instructions instructions Sump free of cracks, holes,and N yes ®yes ®yes ❑yes ❑yes compromised boots? ❑ no ❑no ❑ no ❑ no ❑ no If no,It falls without test in Water,fuel,trash&debris removed III yes CD yes [III yes ❑yes ❑yes from basin prior to test? ❑no ❑no ❑ no ❑ no ❑ no dis se of properly) Height from bottom of sump to highest penetration in inches? 8 8 8 (hydrostatic test only) Starting test level above bottom of sump in inches? 12 12 12 (hydrostatic test only) Test start time 1QQp1D 2:00Pm 1:QQpm Test end time 200om 2:OOom 200Dm minimum 1 hour Measured water level drop in inches accurate to Ill inch none none none (hydrostatic test only) Result of test ®pass inch or me.. [III pass 13 pass O pass O pass (Hydrostatic test fails if level drops 1/8 pfail fail Ofail Ofail Ofail Testers initials and date tested KW 12/14/20 KW 12/14/20 KW 1214/20 Repairs Needed Date of Repair Description of any Repairs ADEM Form 557 03118