HomeMy WebLinkAbout16276 015113 101 12-09-2020 ATGTEST SLA AUTOMATIC TANK GAUGE TEST 52280.94 ATGTEST ADEM ANNUAL TANK GAUGE TEST REPORT FOR YEAR gmn Facility Name: Un ted Food and FUej #11 Owner: McNeill Family Address: 3801 Day St Address: PO Box 11 City, County,Zip: City, State,Zip: Montgomery Al 36101 Facilil I.D.#: _ _ Phone#: 334-263-9070 Tester Name: Kurt a Waltes Tester Phone#: 334-300-0984 Tester Company: Me or Oil Cc Test Date: 12-9-20 Instructions 1. Submit a completed copy of this form within 30 days of performing test to: Groundwater Branch,PO Box 301463,Montgomery,AL 36130-1463,or fez to: (334)270-5631,or email to: USTcompliance(rDadernslabarni . 2. This form allows you to record up to 6 ADEM Unique Tank Numbers,assuming that the Facility ID Number remains the same. 3. Inspection and Testing must be performed in accordance with a nationally recognized code of practice(such as PEI RP-1200 or equivalent)or the manufacturers instructions. 4. Keep a copy of this testing for 3 years. Questions on how to complete this form should be directed to the Groundwater Branch, UST Compliance Unit at(334)270-5655. 5. If the probe is not used for leak detection but the console is(e.g.double walled tanks using interstitial monitoring),then it does not need to be tested. ADEM Unique Tank# 1 2 1 3 Product Stored I Gasoline I Gasoline I Gasoline Automatic Tank Gauge Console Test Does console test history include test ®yes ®yes ®yes ❑yes ❑yes ❑yes alarms?(Don't forget to clear test alarms ❑ no ❑no ❑no ❑no ❑no ❑ no Does site setup agree with configuration 10 yes ®yes to yes ❑yes ❑yes ❑yes shown in console? ❑ no ❑no ❑no ❑no ❑no ❑ no Is battery backup operational? M yes 0 yes M yes ❑yes ❑yes ❑yes ❑ no ❑no ❑no ❑no ❑no ❑ no Testing results? 0 pass ®pass III pass 13 pass 13 pass 13 pass Must meet all applicable criteria to pass. [3 fail 0 fail 0 fail 0 fail 0 fail ❑fail Probe and Float Test Is probe free of residual buildup? ®yes ®yes KI yes ❑yes ❑yes ❑yes ❑ no ❑no ❑no ❑no ❑no ❑ no Are cables free of kinks? ®yes ®yes ®yes ❑yes ❑yes ❑yes ❑ no ❑no ❑no ❑no ❑no ❑ no Was shaft inspected and free of damage? ®yes ®yes III yes ❑yes ❑yes ❑yes ❑ no ❑no ❑no ❑no ❑no ❑ no Do ficats move freely? ®yes ®yes ID yes ❑yes ❑yes ❑yes ❑ no ❑no ❑no ❑no ❑no ❑ no Does measured product and water levels in III yes 0 yes ®yes ❑yes ❑yes ❑yes tank agree with console levels? ❑ no ❑no ❑no ❑no ❑no ❑ no Does actual product float level agree with to yes ZI yes ®yes ❑yes ❑yes ❑yes console product float level? ❑ no ❑no ❑no ❑no ❑no ❑ no Does Overfill alarm activation level agree ID yes 0 Na ID yes 0 n/a ®yes 0 n/a ❑yes 0 n/a ❑yes 0 n/a ❑yes 0 Na with console? ❑ no ❑no ❑no ❑no ❑no ❑ no Does actual water float level agree with ®yes ®yes 0 yes ❑yes ❑yes ❑yes console water float level? ❑ no ❑no ❑no ❑no ❑no ❑ no Does water alarm activation level agree with ®yes ZI yes KI yes ❑yes ❑yes ❑yes console? ❑ no ❑no ❑no ❑no ❑no ❑ no Testing results? El pass 19 pass ®pass 13 pass 13 pass ❑pass (Must meet all applicable criteria to pass.) [3 fall 0 fail 0 fall 0 fall 0 fall ❑fail Repairs Needed Date of Description of any Repairs Repair Tester's Signature: KurtlS WaIt2S ADEM Form 565